PARTS LIST

Item No. Part Number Qty / Pump Description
1 01-0046125 1 Lever Pin—Steel—3/8” x 1‐3/4”
2 02-0000986 2 Cotter Pin
3 03-0008257 1 Lever Link—Cast Iron
4 04-0008235 1 Plunger Pin—Steel
5 05-0008270 1 Packing Gland—Cast Iron
6 06-0008272 5 Gland Packing
7 07-0044073 1 Lever with Drilled Holes
8 08-0008273 1 Cylinder—Cast Iron
9 09-0008275 1 Plunger—Cold Rolled Steel
10 10-0001146 2 Drive Screw
11 11-0000434 2 Hex Hcl Cap Screw
12 12-0046124 1 Link Pin—Steel—3/8” x 2”
13 13-0081647 2 3/4” Check Valve
14 14-0000984 2 3/4” x 2” Nipple—Galv.
15 15-0026677 1 Handel Grip
16 16-0000019 1 Pipe Plug—1/4” Brass
17 17-0039905 4 Push Nut
18 18-0000011 1 Name Plate

PLEASE ORDER BY PART NUMBER
Subject to change without notice

Recommended Procedure to Change out Packing on the 594 TITAN Hydraulic Pressure Test Pump

  1. Disconnect Lever (7) from Plunger (9).
  2. Remove Packing Gland (5) and set aside.
  3. Remove all five rings of old packing (a picking tool or flat head screw driver works).
  4. Clean any dirt or debris from the packing box housing area (a solvent works well).
  5. Dry out the packing box housing with a clean cloth.
  6. Install five each new rings of Gland Packing (6), P/N TI2 06-0008272.
    1. Install each ring of packing so that the “joints” are offset 90 degrees from one another.
  7. Reassemble pump in reverse order.

 

Note: The plunger needs to be installed before installing new packing. This allows the packing to wrap around the plunger. The packing gland can be used to press the packing into the stuffing box.